Designed for harsh environments, Rowe Hankins Ltd. offers a range of residual circuit breaker overload products. Also known as RCBOs or RCBO’s, these products are industry proven for both rail and traction systems.
Precision… made here
Rowe Hankins Ltd. Residual Circuit Breaker Overload products (RCBOs) have two main functions:
The RCBOs are available in 2 and 4 pole configurations – specifically, the 2 pole series 373, and the 4 pole series 368. Additionally, these 2 and 4 pole versions are available at MCB ratings of up to 50 amps and different residual current trip levels.
The circuit uses a current transformer to measure AC current imbalance. The signal is amplified, rectified and then passed to a time delay RCBO circuit. If the signal is present after the delay, then a solid-state switch energises the supply circuit breaker trip coil.
Options for either a fixed time delay or an inverse time delay trip characteristic can be specified. Trip currents can be specified for factory setting at levels between 5 and 300mA (Trips levels up to 2A are possible on a 4 pole series). A unit with a trip level of 5mA is specifically suited for the American market to meet the requirements of the ‘National Electrical Code NFPA 70’.
A wide range of time delay RCBOs can be specified and set during manufacture. The detector circuit power supply is derived from the AC supply. A test signal can be injected through the current transformer from a test button to confirm correct operation.